ReviewsDc Isolation Mini Power

DC Voltage Transducer Voltage Sensor Transmitter Transformer Input 0-100V DC Output 0-10V DC

  • Isolation Resistance:20M Ohm(DC500V) or above.
  • Capacity Max:0-1000V DC (Customerized,contact operator if you need other input ranges,e.g.0-75mV or 0-300V).
  • Power Supply:11-30V DC(any stable power,e.g. 15V dc).
Check Stock

DC Voltage Transducer Voltage Sensor Transmitter Transformer Input 0-50V DC Output 4-20mA DC

  • Isolation Resistance:20M Ohm(DC500V) or above.
  • Capacity Max:0-1000V DC (Customerized,contact operator if you need other input ranges,e.g.0-75mV or 0-300V).
  • Power Supply:11-30V DC(any stable power,e.g. 15V dc).
Check Stock

Loulensy 3-Phase AC Voltage Transducer Sensor Transformer Transmitter 3-Input 0-450V AC with 3-Output 4-20mA DC

  • Capacity Max:0-500V AC (Customerized,contact operator if you need other input ranges,e.g.0-75mV or 0-300V).
  • Impulse Voltage:5KV(peak value),1.2/50uS.
  • Default Frequency:40-60Hz(contact us,if you specially need different frequency,e.g. 100Hz).
  • Load Capacity: 2 times current continuous.
  • Isolation Withstanding Voltage:AC 2.0KV/min*1mA between input/output/power.
  • Feature:Voltage Terminal Insert,standard din rail(35mm)mounting or pannel mounting.
  • Storage Temperature:-40 to 70 degrees Centigrade,20% to 95% without condensation.
  • Working Stability: annual change 003c 0.2%.
  • Working Environment:-10 to 50 degrees Centigrade,20% to 90% without condensation.
  • Isolation Resistance:003e/=20M Ohm(DC520V).
Check Stock

DC Voltage Transducer Voltage Sensor Transmitter Transformer Input 0-200V DC Output 0-5V DC

  • Isolation Resistance:20M Ohm(DC500V) or above.
  • Capacity Max:0-1000V DC (Customerized,contact operator if you need other input ranges,e.g.0-75mV or 0-300V).
  • Power Supply:11-30V DC(any stable power,e.g. 15V dc).
  • Working Stability: annual change 003c 0.2%.
  • Feature:Voltage Terminal Insert,standard din rail(35mm)mounting.
  • Working Environment:-10 to 50 degrees Centigrade,20%-90% without condensation.
Check Stock

DC Voltage Transducer Voltage Sensor Transmitter Transformer Input 0-100V DC Output 0-5V DC

  • Isolation Resistance:20M Ohm(DC500V) or above.
  • Capacity Max:0-1000V DC (Customerized,contact operator if you need other input ranges,e.g.0-75mV or 0-300V).
  • Power Supply:11-30V DC(any stable power,e.g. 15V dc).
  • Working Stability: annual change 003c 0.2%.
  • Feature:Voltage Terminal Insert,standard din rail(35mm)mounting.
  • Working Environment:-10 to 50 degrees Centigrade,20%-90% without condensation.
Check Stock

Current Transmitter Current Transducer Transmitter Transformer Sensor AC Current Converter 0-50A

  • Mutual inductance current monitoring, high current detection accuracy, stable performance, safe isolation of input and output..
  • The measured current of this current transmitter is AC 0-10A/20A/50A.
  • The output signal of this current transducer is DC: 0‑5V/0‑10V/4‑20mA 3 forms are optional..
  • With strong overload capacity, high accuracy, high isolation, high safety, low power consumption.
  • through‑core structure design, isolation withstand voltage up to 2000VAC.
  • hysteresis less than 1%, can be used under strong magnetic field conditions..
  • The shell is made of self-extinguishing material ABS.
  • it is easy to install and use, and there is no need to connect DC in series in the circuit when measuring..
Check Stock

DC Voltage Transducer Voltage Sensor Transmitter Transformer Input 0-200V DC Output 0-10V DC

  • Isolation Resistance:20M Ohm(DC500V) or above.
  • Capacity Max:0-1000V DC (Customerized,contact operator if you need other input ranges,e.g.0-75mV or 0-300V).
  • Power Supply:11-30V DC(any stable power,e.g. 15V dc).
  • Working Stability: annual change 003c 0.2%.
  • Feature:Voltage Terminal Insert,standard din rail(35mm)mounting.
  • Working Environment:-10 to 50 degrees Centigrade,20%-90% without condensation.
Check Stock

DC Voltage Transducer Voltage Sensor Transmitter Transformer Input 0-1000V DC Output 4-20mA DC

  • Isolation Resistance:20M Ohm(DC500V) or above.
  • Capacity Max:0-1000V DC (Customerized,contact operator if you need other input ranges,e.g.0-75mV or 0-300V).
  • Power Supply:11-30V DC(any stable power,e.g. 15V dc).
  • Working Stability: annual change 003c 0.2%.
  • Feature:Voltage Terminal Insert,standard din rail(35mm)mounting.
  • Working Environment:-10 to 50 degrees Centigrade,20%-90% without condensation.
Check Stock

DC Voltage Transducer Voltage Sensor Transmitter Transformer Input 0-50V DC Output 0-10V DC

  • Isolation Resistance:20M Ohm(DC500V) or above.
  • Capacity Max:0-1000V DC (Customerized,contact operator if you need other input ranges,e.g.0-75mV or 0-300V).
  • Power Supply:11-30V DC(any stable power,e.g. 15V dc).
  • Working Stability: annual change 003c 0.2%.
  • Feature:Voltage Terminal Insert,standard din rail(35mm)mounting.
  • Working Environment:-10 to 50 degrees Centigrade,20%-90% without condensation.
Check Stock

DC Voltage Transducer Voltage Sensor Transmitter Transformer Input 0-200V DC Output 4-20mA DC

  • Isolation Resistance:20M Ohm(DC500V) or above.
  • Capacity Max:0-1000V DC (Customerized,contact operator if you need other input ranges,e.g.0-75mV or 0-300V).
  • Power Supply:11-30V DC(any stable power,e.g. 15V dc).
  • Working Stability: annual change 003c 0.2%.
  • Feature:Voltage Terminal Insert,standard din rail(35mm)mounting.
  • Working Environment:-10 to 50 degrees Centigrade,20%-90% without condensation.
Check Stock

DC Voltage Transducer Voltage Sensor Transmitter Transformer Input 0-1000V DC Output 0-10V DC

  • Isolation Resistance:20M Ohm(DC500V) or above.
  • Capacity Max:0-1000V DC (Customerized,contact operator if you need other input ranges,e.g.0-75mV or 0-300V).
  • Power Supply:11-30V DC(any stable power,e.g. 15V dc).
  • Working Stability: annual change 003c 0.2%.
  • Feature:Voltage Terminal Insert,standard din rail(35mm)mounting.
  • Working Environment:-10 to 50 degrees Centigrade,20%-90% without condensation.
Check Stock