ReviewsFatek Plc

DC12-36V 16 Channel PLC Amplifier Board,PLC Signal Amplifier Board,Isolation Relay Module,NPN Input PNP Output,Drilling,PCB Module Rack Installation

  • Can be used to protect PLC internal relays..
  • Effectively avoid system instability caused by mutual interference..
  • Effectively protected the output nodes of the PLC..
  • Can directly replace traditional relays, reducing maintenance time and costs..
  • Hole punching and PCB module mounting are more convenient..
Check Stock

SHENYANG 5 Pack MR-BAT ER17330V3.6V A6BAT PLC Battery for FANUC CNC System Power

  • ★ Battery Model Number : A6BAT Battery- Size 2/3A 3.6V Lithium Battery.
  • ★ 3.6v lithium battery with wire lead and connector ,2 wire 2-pin connector.
  • ★ Battery- Size 2/3A 3.6V Lithium Battery ; Dimensions battery: ø17 mm x 33.6 mm.
  • ★ Other applications: Alarm system, PLC memory backup power supply, CNC system, servo motors, machine tools, instruments, special electronic equipment, etc..
  • ★ Package Included: 5 x A6BAT ER17330V PLC Battery.
Check Stock

UBay New Proscan Curtis Replacement TV Remote Fit for PLED4274A PLED2845A PLDED4016A PLED4011A

  • No Programming Required ! Put batteries in and work (Battery NOT include).
  • If not work directly, you may need to clear the TV's memory first. Please turn off the TV, unplug the power cord, wait for 30 seconds, then replug in the power cord, turn on the TV, and try the remote again..
  • Compatible with Proscan PLED2694A PLC3708A PLCD3283A PLCD3717A PLCD4692A PLDED3273A TV PLED2694A PLC3708A PLCD3283A PLCD3717A PLCD4692A PLDED3273A PLED2243A TV.
Check Stock

GCAN-205 Modbus TCP to CAN Converter, Allows User to Connect Some ModTCP Master with an existing CAN Network

  • The GCAN-204 is a CAN to Modbus RTU Slave Converter with one Serial interface and one CAN interface. It allows user to connect some Modbus Master (for example: PLC, HMI, etc) with an existing CAN network. It has integrated isolation protection module and easier to install with DIN-rail..
  • CAN industrial automation control system.
  • The serial communication device is connected to CAN-bus.
Check Stock

Fafeicy 12-Channel DC12-36V PLC Signal Amplifier Board Isolation Relay Module Amplifier Board with NPN Input PNP Output

  • Protection function: The relay can effectively avoid system instability caused by mutual interference, effectively protect the output node of the PLC, ensure the normal transmission of the signal, and thereby protect the relay..
  • Uses: The relay module can be used to protect the PLC internal relays, which can directly replace traditional relays, reducing maintenance time and cost.
  • Stable performance: The signal amplifier is made of high-quality electronic components with stable and reliable performance..
  • Easy to install: It is recommended to design to make drilling and module installation more convenient..
  • After-sales service: We strive to provide you with the highest quality product and the best customer experience, if you're not entirely satisfied, please just feel free to contact us at any time..
Check Stock

Agatige Frequency to Voltage Converter Module, 0-10Khz to 0-10V F/V Digital to Analog Converter Conversion Module

  • FUNCTION: The frequency of the pulse signal 0HZ to 10KHZ converts into an analog voltage signal of 0-10V. Can be used to interface switching between the PLC and the frequency converter, or interface matching such as the matching of motion control card and inverter control..
  • FEATURES: Input pulse level is 5V 12V 24V, which can be directly entered without serial resistor. The input signal frequency must maintain more than 0.5 seconds..
  • ANTI-INTERFERENCE: Conversion module's signal inputs with optical coupling isolation, which can ensure that the capability of anti-interfence..
  • APPLICATION: Frequency to Voltage Converter Module Can be used for industrial control panel PLC or other signal interface switching.
  • MAJOR SPECIFICATIONS: Output current: 5MA,Voltage: 0-10V, Input pulse level: 5V 12V 24V, Frequency: 0 to 10KHZ..
Check Stock

WSDMAVIS 2Pcs PWM to Voltage Module 0% -100% PWM Converted to 0-10V Voltage Digital Analog Signal Converter for PLC Signal Interface Switching

  • The PWM transfer voltage module LC-LM358-PWM2V converts the PWM digital signals into 0 to 10V analog signals.Allowable error:5%..
  • It can be used as signal interface switching for PLC or other industrial control boards. The output voltage is regulated by adjusting the duty ratio of the PWM..
  • The modules are small in size and easy to use in different places.Easy to operate, fine tuned by potentiometer..
  • MCU embedded technology.Work Voltage:DC 12V-30V(Power requirements:> 100MA).
  • Select the PWM signal input level range through short-circuit.The peak of 4.5V to 10V level. The short cap install in ‘5V’. This level is used for normal controller or 5V MCU.
  • The peak of 12V to 24V level, so inserted in 24V. The short cap install in ‘24V’. This level is used for normal PLC controller..
Check Stock

YVO Optocoupler Isolation Board,4 Channel Optocoupler Isolation Module PLC Signal Level Voltage Conversion Board,Can be Used for Signal Isolation,Signal Level Voltage Conversion (24V to 5V)

  • 【Widely Use】: Our optocoupler isolation board can be used for signal isolation, PLC signal level converting, level conversion between single-chip microcomputer, PLC and other signals, PNP / NPN signal to NPN signal, signal level voltage conversion and other purposes..
  • 【20K Limit Switching Frequency】: The maximum switching frequency of our optocoupler isolation is 20K..
  • 【Easy To Recognise】: Each channel of our optocoupler isolator module has been equipped with indicator, easier to recognise the working status..
  • 【Size Parameters】: Module Dimensions: 72*55*18mm (length*width*height). Mounting Hole Size: 64*47mm. Mounting Hole Diameter: 3mm..
  • 【SHOPPING WITH CONFIDENCE】: We are committed to providing you with quality services. If you have any question, please feel free to contact us by sending emails.We will provide after-sales service until you are satisfied..
Check Stock

X AUTOHAUX Engine Coolant Thermostat Housing Assembly for Honda CR-V 1997-2001 for Honda Civic 1991-2003 for Honda Accord 1990-2002 for Odyssey Prelude 19301PAA306 19301PLC315

  • OE Number: 19301-PAA-306, 19301PAA306, 19301-PLC-315, 19301PLC315.
  • Fitment: for Honda Civic 1991-2003, for Honda Civic del Sol 1993-1997, for Honda Accord 1990-2002, for Honda CR-V 1997-2001, for Honda Odyssey 1995-1998, for Honda CRX 1991, for Honda Prelude 1992-1996, for Acura Integra 1990-2001, for Acura Legend 1986-1990, for Acura CL 1997-1999.
  • Brand new and never used, directly replaces the old one and easy installation..
  • Good Replacement: The engine's thermostat regulates the temperature of the engine by controlling coolant flow. A bad or failing thermostat: high temperature reading and engine overheating, low temperature reading and underheated engine, temperature changing erratically, coolant leaks around thermostat housing or under the vehicle. How to fine thermostat: You can find your car's thermostat by starting at the upper radiator hose and following it to where it enters the top of the engine..
  • Package Included: 1 x Thermostat Housing Assembly.
Check Stock

FX1N-14MR Industrial Control Board PLC,DC24V,Programmable Logic Controller Relay Output,Supports for GX-Developer, GX-work2,HMI Connection.

  • FX1N-14MR: Programmable controller with industrial-grade 32-bit MCU, strong anti-interference capability, faster speed, high-quality chip, stable performance, 8 inputs and 6 outputs, online monitoring, online download storage, automatic failure after power on..
  • MR RELAY TYPE: does not support pulse, can be connected to 24V DC load, maximum output current 5A..
  • PLC CONTROLLER: programming port is the port for program upload, download and hmi communication. The program is written in ladder logic programming language, and supports gx-developer, gx-work2 and hmi connection..
  • WIDE RANGE OF APPLICATIONS: It can be flexibly applied to various industrial automation control occasions such as printing, chemical, building materials, packaging, textile, metallurgy, etc..
  • INDUSTRIAL CONTROL BOARD: no analog output, no pulse output, no support for floating point, no support for stepper motor. Support the connection of text screen and touch screen. The baud rate of plc is 9600..
Check Stock

SIEMENS 6ES7 214-1AG40-0xB0 SIMATIC S7-1200 CPU 1214C, Compact CPU

  • ...lay 1A output, Rated current 5A, can directly drive DC solenoid valve, AC solenoid valve, AC contactor, AC motor, etc..
  • Built-in Analog Input and Output -- Built-in Analog input AD, corresponding to internal data register D5030.(Not D8030) Built-in Analog output DA, corresponding to internal data register D5101..
  • The PLC with Two Programming Port -- The TTL interface and the 232 interface. The 232 interface, you can directly use the USB-232 serial port with a computer to download the program directly. When the PLC need to connect with the touch screen or text, can be used to connect 232 programming port..
  • Buy it Confidence: Let you feel safe using, so you have a better using experience. Great value for money. If you have any problems, please fell free to contact us anytime. Our team will help you solve the problem as soon as possible..
Check Stock