ReviewsHigh Resolution Thermocouple

3\ Outside Air Kit for Pellet Stoves with 3\ Air Intake Pipe Including Harman Stoves 3\ X 10'

  • QuadraFire Thermocouple 800, 1000, 1100i, 1200, 1200i Pellet Stoves 812-0210.
  • Top Quality Aftermarket Replacement Part.
  • The Thermocouple is the device that monitors the fire after start-up. Once it reaches temp the thermocouple allows the stove to start feeding on it's own in normal operation mode. If your stove goes out after the initial start-up cycle, more than likely the thermocouple needs to be replaced..
  • Designed Specifically for the above mentioned models.
Check Stock

Montague OVEN THERMOCOUPLE 48\ 1036-7

  • K-type thermocouple connector with real chromel alumel contacts.
  • Miniature or mini k-type connector dimensions.
  • Works with all k-type thermocouple wires and extension wires.
  • Set of 10 male mini thermocouple connector plugs.
  • Compatible with thermocouple plugs from other manufacturers.
Check Stock

PerfectPrime TC41, 4-Channel K-Type Digital Thermometer Thermocouple Sensor -200~1372°C/2501°F

  • 4-Channel K-Type Digital Thermometer Thermocouple Sensor.
  • Measurement Temperature range: – 200°C ~ 1372°C (-328°F ~ 2501°F).
  • K Type Temperature resolution : 1000°C : 1°C/°F / K.
  • Item includes: 1 x Meter and 4 Probe sensor (length ~ 95cm each, -30°C to 300°C).
Check Stock

Emerson H06F 36 Universal Junction Block Thermocouple 36 inch

  • 36 inch junction block thermocouple with energy cut-off.
  • Stainless steel element construction for prolonged thermocouple life.
  • Standard coaxial thermocouple 11/32 inch double lead thread.
  • Universal adapter fittings included with each kit for replacing thermocouple in most types of pilot burners.
  • Works for both LP and natural gas applications.
Check Stock

PATIOSIR Patio Gas Heater Dump Switch, Outdoor Heater Replacement Parts Thermocoupler &Tilt Switch, Garden Heater Igniter Repair Parts

  • ☆The head of thermocouple is fixed thread, need to be compared that it is suitable for your heater before purchasing the product..
  • ☆Made of high-standard brass and red copper,and ABS materials, during operation, you need to hold the valve for 5-10 seconds and then thermocouple will start work..
  • ☆Suitable for Propane gas heaters with Thermoelectric Safety, such as room gas heater, outdoor patio heater and other Thermoelectric gas products..
  • ☆The thermocouple is easy to install. The probe is connected to the ignition device, the thermocouple is connected to the valve, and the other two ports are connected to the safety dumping switch, which does not require special tools and is prefect compatible for the original part..
  • ☆The safety tipping switch will automatically stop the heater when the heater is tilted or dropped, which can prevent the occurrence of gas leakage when the fire is extinguished and the gas is still on, which is more secure. Suitable for weak dump switches with gas R ≤ 10mΩ..
Check Stock

CGELE PID Temperature Controller Kit Voltage AC 100V to 240V Comes with SSR 40DA Solid State Relay, K Type Thermocouple Sensor, and Black Heat Sink

  • ♥【What You Get】In this PID temperature controller kit,it include 1 x PID temperature controller,1 x solid state relay 40DA,1 x K type thermocouple,1 x heat sink..
  • ♥【Product parameters】Power supply voltage:110-240VAC 50/60Hz.
  • working environment:ambient temperature: 0℃~50℃,relative humidity: 35%~85% (no condensation) ;storage temperature:-25℃~65℃(avoid ice or dew);resolution:1℃,0.1℃(adjustable);wiring method:terminals;accuracy:+0.5%FS.
  • installation environment:installation type ll, pollution grade 2 (IEC61010-1).
  •  max current: 30mA, load resistance:≥1K..
  • ♥【Feature】 Support 2 wire thermocouple input,1 way solid state relay output,1 way relay alarm output.
  • digital display of real-time and set temperatures,adjustable degrees ℉ and ℃..
  • ♥【Size】The panel size of PID temperature controller is 48(W)mmx48mm(L),install hole size is 46(W)mmx46mm(L).Total size:48mm(W)x48mm(L)x76mm(H).
  • ♥【Widely application】Widely used in chemical industry, medical industry, product industry, machinery industry, greenhouse farming, agricultural planting, etc..
Check Stock

High Temperature Ceramic K-Type Thermocouple Terminal Block

  • Unglazed Ceramic Thermocouple Connector Block for High Temperature K-type Thermocouples.
  • Connectors are made from Nickel Plated Brass, Accept AWG 8 (3.3 mm) K-type Thermocouple.
  • Big Terminal Screws for Easy Wiring, Accepts Stranded or Solid Wire.
Check Stock

Very High Temperature K-Type Thermometer with Ceramic Insulated Probe Sensor for Kiln Crucible and Forge up to 2372 °F 1300 °C Model CR-8

  • High Temperature K-type Thermocouple with ceramic tube insulation.
  • Temperature Range: -328 to 2498 °F (-200 to 1370 °C), Class 1 or Select Grade K-type Thermocouple wire.
  • Very thick AWG8 (3.2 mm) Thermocouple Wire, Total length 18.5 inch, insulated length 16.5 inch.
  • Oval insulator with a max diameter of 0.5 inch, 1 inch long insulator segments.
  • Large LCD display: 3 1/2 digits and Easy switch between °F and °C.
Check Stock

K Type Thermocouple Temperature Thermocouple Sensor Temperature Detector Temperature Gauge with M4 Thread for 3D Printer Temperature Sensor

  • Type K (chromel–alumel) is the most common general-purpose thermocouple with a sensitivity of approximately 41 µV/°C.[10] It is inexpensive, and a wide variety of probes are available in its −200 °C to +1350 °C (−330 °F to +2460 °F) range. Type K was specified at a time when metallurgy was less advanced than it is today, and consequently characteristics may vary considerably between samples. One of the constituent metals, nickel, is magnetic.
  • a characteristic of thermocouples made with magnetic.
  • They operate very well in oxidizing atmospheres. If, however, a mostly reducing atmosphere (such as hydrogen with a small amount of oxygen) comes into contact with the wires, the chromium in the chromel alloy oxidizes. This reduces the emf output, and the thermocouple reads low. This phenomenon is known as green rot, due to the color of the affected alloy. Although not always distinctively green, the chromel wire will develop a mottled silvery skin and become magnetic. An easy way to check for t.
  • Hydrogen in the atmosphere is the usual cause of green rot. At high temperatures, it can diffuse through solid metals or an intact metal thermowell. Even a sheath of magnesium oxide insulating the thermocouple will not keep the hydrogen out..
Check Stock

Cooper Atkins 35132 Aquatuff with Wrap&Stow Duraneed

  • Waterproof Thermocouple Thermometer - Precise digital thermocouple thermometer, delivers a true +/- 0.9 degrees Fahrenheit accuracy and probes can be replaced in the field without the need for recalibration.
  • Heavy Duty Probe Cable - Patented thermocouple thermometer probe cable that neatly wraps and stows around the instrument. Uses any K Type probe.
  • DuraNeedle Probes - Best used for dense meats. Also works well with soft foods and liquids. Probe is calibrated with instrument for Total System Accuracy.
  • Waterproof Digital Thermocouple - Large easy to read digital LCD display, auto shutoff after 10 minutes of non-use. IPX7 waterproof rated.
  • Cooper-Atkins Corporation - Headquartered in Middlefield, CT, Cooper-Atkins has been a leading manufacturer of quality time, temperature, and humidity instruments serving the Foodservice, HVAC and Healthcare markets since 1885.
Check Stock

GBC Document Camera, Discovery 3000 (DCV10004)

  • pyrometer Temperature range: -50°C to 1300°C ( -58°F to 2372°F) and Overload display alert when input exceeds measurement range pyrometer. Thermocouple Temperature range: -50°C to 1000°C ( -58°F to 1832°F).
  • Designed for use with K-type thermocouples and Selection between Celsius and Fahrenheit.
  • Decimal or round number display selectable (decimal range is -58.0F to999.9F and round number range is -58F to 2372F).
  • Includes 2 Thermocouples ( One 3" K type temperature probe (-58 – 752 °F) and one Kiln Heavy duty K type Thermocouple ( -58°F to 1832°F) and Digital Pyrometer, 9V battery and Manual.
  • Thermocouple Measurement range: 32 - 1832 °F (0 - 1000 °C) Thermocouple Type: K Type Cable length : 3 ft Sensing tip length: 6" (150mm) Stainless Steel Sensing tip diameter: 0.19" (5mm) Thread width : 5/16" (M8) Internal Insulation: Fiber Glass External shielding: Metal Shield (Stainless steel braided).
Check Stock