ReviewsReal time Thermocouple

Multi Channels Digital Industrial Thermometer Temperature Data Logger (AT4716)

  • Test range: -200 ° C ~ 1800 ° C Resolution: 0.1 ° C Accuracy: 0.2% ± 1.
  • AT4808 handheld multi-channel temperature meter adopts high-performance ARM micro processor, can collect multi-channel temperature data simultaneously and response quickly..
  • AT4808 has the function of checking broken thermocouple, high/low beep function and communication transmission. 128 channels temperature data can be extended, compatible with various temperature sensors. Equipped with Mini-USB (virtual series port) interface to realize data acquisition, analysis and print through the standard computer software. Support USD disk storage, real-time sampling data storage. The users can adjust data for each channel independently..
Check Stock

Amprobe TMD-56 Multi-Logging Digital Thermometer, 0.05% Basic Accuracy

  • Portable, dual-input thermometer for reading temperatures from two sources simultaneously, and USB data transfer, and is used in quality control and HVAC, electrical, industrial, and automotive maintenance.
  • Accepts K-, J-, T-, E-, R-, S-, and N-type thermocouples.
  • Dual-scale temperature readings range from -328 to 2,498 degrees F (-200 to 1,370 degrees C).
  • Dual-input thermocouples for superheat and subcool applications, and cut-out and cut-in temperature measurements, and offset mode compensates for thermocouple error.
  • USB port exports data, and built-in memory saves up to 16 sets of data with 16,000 data points, and datalogging saves up to 256 samples with real-time data.
Check Stock

Amprobe TMD-50 Thermocouple Thermometer K-type

  • Portable, dual-input thermometer for reading temperatures from two sources simultaneously, and is used in quality control and HVAC, electrical, industrial, and automotive maintenance.
  • Dual-scale temperature readings range from -328 to 2,498 degrees F (-200 to 1,370 degrees C).
  • Dual-input thermocouples for superheat and subcool applications, and cut-out and cut-in temperature measurements, and offset mode compensates for thermocouple error.
  • Backlit LCD screen with a data hold feature to save temperature readings for later viewing, maximum and minimum temperature with elapsed time, average and relative temperature calculations, and low battery indicator.
Check Stock

GBC Document Camera, Discovery 3000 (DCV10004)

  • pyrometer Temperature range: -50°C to 1300°C ( -58°F to 2372°F) and Overload display alert when input exceeds measurement range pyrometer. Thermocouple Temperature range: -50°C to 1000°C ( -58°F to 1832°F).
  • Designed for use with K-type thermocouples and Selection between Celsius and Fahrenheit.
  • Decimal or round number display selectable (decimal range is -58.0F to999.9F and round number range is -58F to 2372F).
  • Includes 2 Thermocouples ( One 3" K type temperature probe (-58 – 752 °F) and one Kiln Heavy duty K type Thermocouple ( -58°F to 1832°F) and Digital Pyrometer, 9V battery and Manual.
  • Thermocouple Measurement range: 32 - 1832 °F (0 - 1000 °C) Thermocouple Type: K Type Cable length : 3 ft Sensing tip length: 6" (150mm) Stainless Steel Sensing tip diameter: 0.19" (5mm) Thread width : 5/16" (M8) Internal Insulation: Fiber Glass External shielding: Metal Shield (Stainless steel braided).
Check Stock

Inkbird PID Temperature Controller Kit High Voltage 100ACV to 240ACV Comes with SSR 40DA Solid State Relay K Type Thermocouple and White Heat Sink

  • 【Alarm Output】With one alarm relay output: AC250V 3A (Resistive load) ON/NC, you may connect it with a buzzer..
  • 【Supports 3 Wires Sensors】3 wires sensor or 2 wires sensor, like K type thermocouple and Cu500, are supported by this PID temperature controller.
  • 【SSR Output】With one relay output for external SSR, SSR or relay is a must for this temperature controller. A 40DA SSR is included.
  • 【Digital Display ℃/℉】It’s a digital PID controller but also supports Centigrade and Fahrenheit reading.
  • 【2 Temp Displaying Windows】The real-time temperature and the setpoint are shown at the same time.
Check Stock

Coolrunner Gas Patio Heater Repair Replacement Parts Outdoor Heaters Safety Kits Thermocouple (M8 x1) and FD4 Dump Switch for Propane Gas Patio Heater

  • Well Made & More Safe: The thermocouple is made of brass and red copper and the anti-tilt switch, made of ABS, which will automatically stop heating when the gas heater is tilted..
  • Wide Compatibility: The patio heater thermocouple replacement is suitable for most of propane heater, patio heater and other gas heaters with thermoelectric safety..
  • Dimension: The total length of thermocouple is 350mm, thermocouple probe is M6*0.75 and threaded end is M8*1, please measure your original parts before ordering. Weak current FD4 dump switch is for gas R≤10 mΩ..
  • Easy to install: It is easy to replace just follow the way you remove the defective part. Notice: Keep the thermocoupler probe about 5mm from the burner hole..
  • Great Value for Money: If the thermocouple or dump switch of your gas heater is broken, you just need to change the replacement that will save $200 for you..
Check Stock

UNI-T UT701 Single Function Temperature Calibrator

  • 1. Up to 0.05% output accuracy 2. 6-digit display 3. Output functions: DC voltage, resistance, thermocouple, and thermal resistance.
  • 4. 10 thermocouple scales 5. 4 thermal resistance scales 6. High precision automatic cold junction compensation for thermocouple outputs.
  • 7. Manual stepping and automatic stepping and ramping 8. Stores and recalls setups.
Check Stock

Upgraded 9003542 Natural Gas Pilot Assembly 9003542 Pilot Assembly Replacement for Natural Gas Water Heater,100109295 18324-190 Water Heater Parts Compatible with A.O.Smith Kenmore State GS and GSX

  • Excellent Quality:Upgraded 9003542 nat gas pilot assembly use high-quality raw materials which has undergone extensive testing by suppliers to ensure longer durability. 9003542 pilot assembly can perfectly solve the problems of water heater pilot light kept going out and water heater not heating due to thermocouple damage.Part may differ in appearance but is a functional equivalent to prior parts including:183824-190,9003530 pilot assembly..
  • Widely Applicable & Perfect Fit:9003542 natural gas pilot assembly can perfectly replace 183824-190, 9003542005,100109295 pilot assembly. Fits following brands and models:Kenmore water heater parts▶▶153333315HA, 153333316HA, 153333345, 153333346, 153333347, 153333445, 153333446, 153333447, 153333850,etc. A.O. Smith water heater parts ▶▶A.O. Smith FCV40, FCV50, GCV30, GCV50, GCVH30, GCVT40, GCVT40Q, GVR40, XCV30, XCV40, XCV50, XCVH30, XCVL40, XCVT40, XCVT40L,etc. State GS and GSX water heater parts▶▶ GS665HRRT100, GS665YRRT100, GS665YRRT101, GSX65HRRT100, GSX65YRRT100, etc..
  • Easy to Install:9003542 water heater pilot assembly is very easy to install. Shutting gas off, pull entire burner assembly. Take out the 2 screws on the mounting plate and remove old thermocouple and spark ignition. Gently unr....
Check Stock

ennoLogic Volt mA Thermocouple Loop Process Calibrator eC370T - 0-20V and 4-20mA Simulator – Portable Millivolt mA and Temperature Signal Generator and Meter for Transmitters Current Loops PLC

  • VERSATILE AND ACCURATE VOLT MA THERMOCOUPLE CALIBRATOR: Signal generator, simulator and volt / mA meter for calibrating, testing and repairing milliamp loops, thermocouples, PLC, temperature control and HVAC systems. Easily generate precise test signals for current and voltage devices (mA, mV, V, Celsius and Fahrenheit ranges)..
  • NUMERIC KEYPAD for ease and flexibility in setting output signals configuring options. HOTKEY programming for each numeric key (long-press immediately outputs user-configured voltage, current or temperature signal). RAMP AND LADDER OUTPUT FUNCTIONS can be custom configured. BUILT-IN 24V LOOP SUPPLY lets you power and read a device or transmitter without needing another multimeter. This greatly simplifies testing 2-wire current loops..
  • MEASURE VOLTAGE OUTPUT SIGNALS from process devices and sensors with two input ranges of 0-100mV (0.01mV resolution, 0.06% accuracy) and 0-20V (1mV resolution, 0.08% accuracy). MEASURE CURRENT TRANSMITTERS within a range of 0 to 24mA with 0.001mA resolution and 0.08% accuracy. MEASURE THERMOCOUPLE TEMPERATURES within a range of -250°C to +1800°C and resolution of ±0.7°C to ±2°C (range and resolution depends on thermocouple type, supported are type K, J, E, T, N, S, R, and B.).
Check Stock

Bakers Pride M1296X 72 Long T46 Thermocouple

  • K-type Thermocouple wire for making thermocouple or extension wire, up to 752 °F (400 °C).
  • Chromel / Alumel type K thermocouple wire with Standard Accuracy: +/- 2.2 °C or +/- .75%.
  • The K-type wires are AWG 24 (0.51 mm) in diameter.
  • ANSI color coded braided fiberglass insulation, red = -, yellow = +.
  • 10 yard ( 30 ft ) roll, wire is flexible and easy to bend to shape.
Check Stock

Aupoko Patio Heater Thermocouple, Outdoor Heater Replacement Parts M8 x 1 End Connection Nuts Thermocouple 410 mm Length M6 x 0.75 Head Thread with 6.3 MM/0.25'' Flat Terminal

  • COMPATIBILITY: The thermocouple for gas patio heater is suitable for BBQ grill, fire pit, fireplace, heater hose connection..
  • EASY INSTALLATION: You only need less than 5S to open valve..
  • PREMIUM QUALITY: High standard solid copper and brass material, firm construction for durability and longevity..
  • DIMENSION: Universal thermocouple with M6x0.75 thread on head, M8 x 1 end connection nuts thermocouple..
  • WARRANTY: The patio heater thermocouple complies with 1- Year limited warranty, if there any question, please feel free to contact us..
Check Stock