ReviewsThree Phase Induction

Siemens 3UG4631-1AA30 Monitoring Relay, Single Phase Voltage Monitoring, Screw Terminal, 1 CO Contacts, 0.1-60VAC/DC Measuring Range, 0.1-30V Hysteresis, 0-20s Delay Time, 24VAC/DC Auxiliary Voltage

  • Features: Undervoltage protector integrates three-phase voltage protector, chronograph and counter in one.
  • Multifunction: The protection relay has protection functions such as overvoltage, undervoltage, phase loss, phase sequence, three-phase voltage unbalance, etc.
  • Practical functions: The voltage monitoring relay has functions such as start-up delay and output test. 2 rest module optional, manual and automatic.
  • Specification: Monitoring Circuit: L1, L2, L3.
  • LCD Display: LCD data display, easy to read, no external power supply required.
Check Stock

Voltage Monitoring Relay Protection 3-Phase AC 220-440V Small Size Phase Sequence Protection Phase Sequence Relay for Industry Applications

  • Dynamic phase loss, static phase loss protection: refers to the phase failure of any phase when the protected device is in the running state or non-operating state. The indicator light is in the form of red light and priority.
  • Wrong phase protection: A protection measure to prevent the phase sequence of L1, L2, L3 three-phase AC power supply from being connected incorrectly. Instant action. The indicator light is in the form of yellow light..
  • Voltage Unbalance Protection: Refers to a voltage imbalance that will affect the safe operation of the device. When the voltage imbalance rate is higher than 8%. The form of the indicator light is: the lack of phase red light is on, and priority..
  • Delay protection: When there is a fault, the monitor will delay after 1~2 seconds, and the relay will release..
  • The protection function of the monitor is not affected by the current of the line or load, the inrush current, the unbalanced current and the nature of the load. Long-term work with full performance and full climate. Power consumption is no more than 2W..
Check Stock

YWBL-WH Monitoring Relay,JVRD6 Phase Sequence Protection Relay Monitoring Voltage Control Device

  • Function: Three-phase monitoring of phase sequence, phase loss..
  • Application: This monitoring relay is suitable for pumps, fans, blowers, motor elevators, cranes, central air conditioners, etc..
  • Construction and installation: This phase sequence relay uses standard modular construction and rail-mounted mounting..
  • Power supply mode: Powered by the measurement circuit, no additional auxiliary power supply is required..
  • Accessories: With 2 indicators to indicate various working conditions, the two groups usually open/close contacts..
Check Stock

TG30S Mini AC 220-440V Voltage Monitoring Relay Phase Sequence Protection Protection 3-Phase Phase Sequence Relay for Industry Applications

  • Dynamic phase loss, static phase loss protection: refers to the phase failure of any phase when the protected device is in the running state or non-operating state. The indicator light is in the form of red light and priority.
  • Wrong phase protection: A protection measure to prevent the phase sequence of L1, L2, L3 three-phase AC power supply from being connected incorrectly. Instant action. The indicator light is in the form of yellow light..
  • Voltage Unbalance Protection: Refers to a voltage imbalance that will affect the safe operation of the device. When the voltage imbalance rate is higher than 8%. The form of the indicator light is: the lack of phase red light is on, and priority..
  • Delay protection: When there is a fault, the monitor will delay after 1~2 seconds, and the relay will release..
  • The protection function of the monitor is not affected by the current of the line or load, the inrush current, the unbalanced current and the nature of the load. Long-term work with full performance and full climate. Power consumption is no more than 2W..
Check Stock

Mini AC 220-440V TG30S Phase Sequence Protection Voltage Monitoring Relay Voltage Phase Protective Relay Building Electronics Projects for Industry Applications

  • Dynamic phase loss, static phase loss protection: refers to the phase failure of any phase when the protected device is in the running state or non-operating state. The indicator light is in the form of red light and priority.
  • Wrong phase protection: A protection measure to prevent the phase sequence of L1, L2, L3 three-phase AC power supply from being connected incorrectly. Instant action. The indicator light is in the form of yellow light..
  • Voltage Unbalance Protection: Refers to a voltage imbalance that will affect the safe operation of the device. When the voltage imbalance rate is higher than 8%. The form of the indicator light is: the lack of phase red light is on, and priority..
  • Delay protection: When there is a fault, the monitor will delay after 1~2 seconds, and the relay will release..
  • The protection function of the monitor is not affected by the current of the line or load, the inrush current, the unbalanced current and the nature of the load. Long-term work with full performance and full climate. Power consumption is no more than 2W..
Check Stock

Phase Rotation Meter, SP8030 3 Phase Battery Free Phase Sequence Detector for Industry for Electrician

  • Professional choice: check the phase sequence and indicate whether the phase is open..
  • Large measuring range: the indicator can check three-phase AC voltage from 200V to 480V, with excellent performance..
  • The results are clear at a glance: LED lights can display phase loss and support buzzer instructions..
  • Safe and secure: equipped with a clip to facilitate contact with the terminal to ensure safety and reliability..
  • Portable design: small and light, with a portable bag, easy to carry..
Check Stock

VFD 220V 0.75KW 1hp Variable Frequency Drive CNC VFD Motor Drive Inverter Converter for Spindle Motor Speed Control HUANYANG HY-Series(0.75KW, 220V)

  • IMPORTANT NOTE: this VFD is applicable to THREE phase motor and NOT support external resistor.Fan runs all the time even though the motor isn't (fan functions need to be customized)..
  • This drive is very suitable for HIGH-SPEED ROTATION motors,such as spindle motor, engraving machine CNC.Work with 220V single phase input and 220V three phase input.you can just connected L1/L2 to any two of VFD input R/S/T.
  • This VFD can be used for constant torque loads (such as hard starting: Air compressors, HVAC units) and variable torque loads (such as pumps, fans, etc). It can be used as a motor speed control and a phase converter.This item use Sine wave PWN(SPWM) for the control system.It is designed which also could use USA 60hz single phase input.Can work well with the Mach 3 controller.
  • Application: Spindle motor.CNC router, CNC machine, milling machine, drilling machine, wingding machine, mixer, extruder, slitter, winder, compressor, ventilator, pump, grinder, conveyor, elevator, centrifuger and other speed control machines.
  • If there are problems in use after you receive,please don't give us negative or natural feedback.Please contact us as soon as possible, we will help you solve problems or help you replace new one ..
Check Stock

Grizzly Industrial G0513-17" 2 HP Bandsaw

  • Blade sizes available 1/8-Inch - 1-Inch • Standard blade length: 131 1/2-Inch • Blade speeds: 2 speeds 3500 1600 FPM • Approximate ship.
  • Motor: TEFC capacitor start induction 2 HP single-phase/60 Hz 110V/220V • Amps: 20/10 • RPM: 1725 • Power transfer: Belt d.
Check Stock

Grizzly G0514X Extreme Series Bandsaw 3 HP 19-Inch

  • Motor: 3 HP 220V single-phase TEFC capacitor start induction 60 Hz pre-wired 220V.
  • Overall size: 78-InchH x 36-InchW x 32-InchD.
  • Wheels: fully balanced cast iron with polyurethane tires • Wheel covers: pre-formed hinged steel.
Check Stock

Grizzly Industrial H2936-28 x 39 Downdraft Table

  • Motor: TEFC capacitor-start induction, 1/2 HP, single-phase, 110V.
  • Non-marring rubber grommets to support work.
  • Two 110V outlets for plugging in portable sanders.
Check Stock

Grizzly Industrial H7587 - Resaw Fence Complete for 14 Bandsaws

  • Motor: 3 HP 220V single-phase TEFC capacitor start induction 60 Hz pre-wired 220V.
  • Overall size: 78-InchH x 36-InchW x 32-InchD.
  • Wheels: fully balanced cast iron with polyurethane tires • Wheel covers: pre-formed hinged steel.
Check Stock